TECORA 氧气分析仪 TOA MP:
主要特点
Electrochemical cell replaceable
Maintenance free
Specific with absolute zero and linear output
Unaffected by flow rate, hydrocarbons
Air calibration
Sensor insulation valves
Main applications:
Gas purity monitoring (N2, H2, Ar, CO2, He,...)
Inertages
Heat treatment atmospheres
Glove-box atmospheres
VCM purity
产品信息
Zero drift : lt .0.1 % signal / month
Sensor : temperature monitored at +40°C
Response time : T95 lt. 20 s
Repeatabilty : +/- 0.5 %
Recommended flow : 0.5 l/min
Power Supply : 115/230 VAC - 50/60 Hz
Weight : 8 Kg
Output signals : 4 - 20 mA, 0 - 1 V, RS232, parallel
Measuring range : 0 – 10 000 ppm (0 - 25% for calibration with air)
Measuring principle : electrochemical sensor
Linearity : +/- 1.0 %
Inlet pressure : 1 bar max
Display : in ppm up to 4999 ppm, in % above
Analogue output range : user selectable between 0 and 10 000 ppm
Accuracy : +/- 1 % of selected full scale +/- 0.2 % between 0 and 10 ppm
Electronic applications (lamp and semi-conductors)
TECORA 氧气分析仪 TOA MP参数:
系统结构:HM-OSP系统由HMP氧探头,OA系列氧含量分析变送仪组成。氧探头和变送仪可以一起安装在测量现场,通过4-20mA将检测的氧含量值远传。
应用领域:适用于热力供暖、电力、能源环保等工业加热装置烟道烟气中氧含量检测。
应用炉型:热力蒸气锅炉、自备电厂锅炉、民用锅炉、焚烧炉等。
TECORA 氧气分析仪 TOA MP参数:
◆运用流体力学原理设计的新型采样探头,自动导入样气,自动清除粉尘。设计有陶瓷过滤器及氧化锆表面保护层,使氧传感器免受高粉尘和腐蚀性气体的污染,进一步提高了氧探头的使用寿命。
◆低电压加热(DC15V),无高压,现场使用维护安全可靠。
◆分体式结构,氧化锆探头可以很方便的从采样探头上卸下,方便维护。